SBC-9138/9238
Multi- Stage Smart Battery Chargers
User Manual
Keep this manual in a safe place for quick reference at all times.
This manual contains important safety and operation instructions for correct use of the battery charger. Read through the
manual and pay special attention to the markings and labels of the charger, battery and equipment connected to the
battery system.
Pay special attention to these two types of notices used in this manual.
WARNING:
Failure to heed this warning may cause injury to persons and damage to Equipment.
CAUTION:
Failure to observe this warning may result in damage to equipment and improper functioning of the Charger.
WARNING:
The charger is designed for in-door use. Protect the charger from ingress of water.
This charger is made to charge only properly sized lead acid batteries.
Don't recharging non-rechargeable batteries.
Charging other types of battery or under-sized lead acid batteries may cause fire or explosion.
Install the charger in accordance with all local codes
Do not use the charger if it has been dropped or damaged.
Do not remove casing of the charger, there is no user-serviceable parts inside.
Do not charge the battery on boats. Remove the battery and charge on shore.
Never attempt to charge a frozen battery
Never attempt to charge a damaged battery.
Wear protective goggles and turn your face away when connecting or disconnecting the battery.
Never place the charger on top of a battery.
Never smoke, use an open flame, or create sparks near battery or charger during normal charging operation as
batteries may give out explosive gas.
Do not charge batteries in an enclosure (box- in) due to possible explosion of entrapped explosive gas.
Use of accessory not recommended may cause risk of fire, electric shock.
Disconnect the mains supply before connecting or disconnecting the links to the battery.
If the charger does not work properly or if it has been damaged, unplug its AC and DC connection.
CAUTIONS:
Refer to battery manufacturer’s specific recommended values for battery type settings and float voltage setting.
Fix the charger to a solid support via three grooves at the flange of chassis, with three screws or nuts.
Ensure all ventilation ports are not obstructed for efficient fan cooling, keep loose soft material or paper off at the vent
holes of the charger.
During charging, the battery must be placed in a well ventilated area.
If longer output charging cord is required, make sure the diameter is adequate for the current in given cable length.
Page view 0
1 2 3 4 5 6 ... 10 11

Summary of Contents

Page 1 - User Manual

SBC-9138/9238 Multi- Stage Smart Battery Chargers User Manual Keep this manual in a safe place for quick reference at all times. This manual contain

Page 2

I. Trouble Shooting PROBLEM INDICATIONS POSSIBLE CAUSES SUGGESTED SOLUTION Charger does not work LCD display not turn on No AC power AC input s

Page 3 - LCD Display Indication

J. Specifications Model SBC-9138 SBC-9238 AC Input Voltage 200-240VAC, 50Hz~ Yes AC Input Current at Full Load (at 230VAC) 2.9A Output (Charge) Volt

Page 4 - B. Battery Type Selection

Fig.1 INTRODUCTION Congratulations on purchasing our new Multi-Stage (IU0U) Switching Mode Smart Battery Charger. This software based MCU control 7

Page 5

3. Recondition mode switch Simple press and hold 3 seconds the switch to set the charger to go with recondition charge in next cycle. 4. Battery

Page 6 - Charging Profile

e. Power level meter Displays current power level (the % of output current selected, details please see section F) f. Charging status NORMAL: C

Page 7

Once Self-Testing completed, the LCD display will show as below and remind you the charger are ready for battery connection. Once

Page 8 - H. Fault Indication

D. Normal Multi-Stage (IUoU) Charging Operation The 7-stage IU0U charge algorithm ensures fast, complete and at the same time gentle charging of t

Page 9

Stage 7. STANDBY MODE - The constant voltage charging In this stage, the charging voltage at this mode will be 4% less than the Float voltage only f

Page 10

G. Temperature Sensor Warning! The temperature sensor must be installed at the Negative Terminal of the battery terminal, wrong connection to the

Page 11 - J. Specifications

F4: Fan stuck or not working F5: Faulty battery F6: Battery temp over 60°C as detected by remote sensor F7: short circuit > 5 sec shut do